LTA tennis court lux levels at a glance
The figures below are the LTA's Appendix A performance standards, from the Floodlighting Guidance Note 2026. They are maintained average illuminance, measured at playing surface level. We have not changed them, and we have not added prices.
| Standard | Principal play area (PPA) | Total play area (TPA) | Uniformity (PPA / TPA) |
|---|---|---|---|
| Recommended | 500 lux | 400 lux | 0.7 / 0.6 |
| Minimum | 400 lux | 300 lux | 0.7 / 0.6 |
The principal play area is the area bounded by the doubles court lines. The total play area is the PPA plus the run-backs of 4.5 m and the side-runs of 2.5 m. For outdoor LED designs the LTA uses a minimum maintenance factor of 0.9. It asks for 45 readings on the PPA and 117 readings on the TPA.
The LTA also says venues with floodlights have, on average, 50% more members, and that lighting outdoor courts adds 35% more playing time between November and April. It gives 2,500 hours a year for an outdoor court without floodlights and 3,500 hours with floodlights, both with a 35% allowance for bad weather. Those are LTA figures, not Polaris measurements.
Planning permission and court layouts
The LTA is direct: all floodlighting schemes in the UK will require formal planning consent from the local authority. Designs should show that the scheme performs on the court and has a limited environmental impact. Incomplete or inaccurate submissions can jeopardise that consent.
Column heights are generally 6 m to 10 m, with the front glazing of each fitting at a tilt of less than 35 degrees to the surface. The guidance note describes three layouts: side lit, corner lit, and corner and side lit. Fence-mounted linear fittings, such as PS-TENNIS, do not need lighting poles. PS-POWER is the mast-mounted option, with a tennis optic of 120 x 45 degrees at 4000K.
If you are converting metal halide lights to LED, check that the current consent was discharged. Columns more than 20 years old need a structural check. If the court is within 30 m of houses, the LTA asks for a specialist design with a model of vertical light trespass. Polaris produces the lux plot and the light-spill drawings, and handles the planning application.
This guide and our tennis court lighting page
This page is the guide: LTA lux levels, how to light a tennis court, layouts, planning permission and a downloadable PDF. Our tennis court lighting page is the service page, with product options and a request for a survey. You may also want our padel court lighting guide, the padel court lighting page, or the sports lighting overview.
Frequently asked questions
How many lux does a tennis court need?
The LTA recommended standard is a maintained average of 500 lux on the principal play area and 400 lux on the total play area, with uniformity of 0.7 and 0.6. The minimum standard is 400 lux and 300 lux, with the same uniformity. Source: LTA Floodlighting Guidance Note 2026.
What is the difference between the LTA recommended and minimum standards?
Both use the same uniformity. The recommended standard is brighter, at 500 lux and 400 lux. The minimum is 400 lux and 300 lux. A lux plot will show which of the two a court can meet.
Do tennis court floodlights need planning permission in the UK?
Yes. The LTA says all floodlighting schemes in the UK will require formal planning consent from the local authority. Incomplete or inaccurate submissions can jeopardise that consent. Polaris produces the lux plot and the light-spill drawings, and handles the planning application.
How high should tennis floodlight columns be?
The LTA generally describes column heights of 6 m to 10 m. Side-lit and corner-lit layouts typically use 10 m columns, with a minimum of 8 m for corner lit. Corner and side lit layouts typically use 6.7 m or 8.0 m columns. Fence-mounted fittings such as PS-TENNIS do not need lighting poles.
Can we convert existing metal halide tennis lights to LED?
Often yes, sometimes on the existing columns. Check that the current planning consent was discharged. Columns more than 20 years old need a structural check. If the court is within 30 m of houses, the LTA asks for a specialist design with a model of vertical light trespass. If the new design meets the existing consent, you can apply for a non-material amendment; otherwise you need a new application.
What is the difference between PPA and TPA?
The principal play area (PPA) is the area bounded by the doubles court lines. The total play area (TPA) is the PPA plus run-backs of 4.5 m and side-runs of 2.5 m.
When do tennis clubs need three-phase power?
The LTA says a club with up to two or three courts may be able to use the existing single-phase supply. More than three floodlit courts usually needs a three-phase supply.
How do I get the tennis court floodlighting guide?
Enter your name, organisation and email in the form on this page. You can download the free 9 page PDF straight away. You can also ask for a free survey if you are planning a project.