Home › Insights › Padel court lighting guide
Free guide (PDF)

Free padel court lighting guide for UK clubs

This padel court lighting guide is for UK club committees and facility managers who want to know how to light a padel court to the LTA and SAPCA standard, how glass walls change the design, what planning permission involves, and how to convert existing lights to LED. The free 8 page PDF is written in plain English, with a checklist. For fittings, a survey and a proposal, see our padel court lighting page.

Cover of the Polaris Light padel court lighting guide
  • LTA and SAPCA lux levels for padel
  • Glass-court layouts, indoor and outdoor
  • Planning permission and converting to LED
  • A project checklist and the sources we used

Get the free guide

Covered padel courts with side-mounted sports lighting

What is in the guide

  1. Why padel lighting is different on a glass court
  2. LTA and SAPCA lux levels, indoors and outdoors
  3. How fittings are mounted on the enclosure or on columns
  4. Covered courts, indoor halls and converting to LED
  5. Planning permission
  6. PS-PADEL-LINEAR and PS-POWER
  7. Checklist and sources

LTA and SAPCA padel lux levels at a glance

The figures below are the minimum illumination at ground level (Z=0) in the LTA Padel Court Data Sheet and in the SAPCA Code of Practice for the Construction of Padel Courts (September 2025). Both documents use the same figures for outdoor and indoor courts. We have not changed them, and we have not added prices.

Level of playAverage illuminance (E av)Uniformity
National and international competition500 lux0.7
Regional competition, school and recreational use300 lux0.5

Both documents ask for a 10% over-performance in the initial design, described as a 0.9 maintenance factor, and for a 1.0 m by 1.0 m calculation grid centred on the net line. Fittings must leave at least 6.0 m of clear height above the playing area. For new build, 8.0 m is recommended where it is feasible. Those are LTA, SAPCA and FIP height figures, not Polaris measurements.

Glass courts, layouts and planning permission

Padel is played off the glass and mesh walls, so glare and vertical light matter more than on an open court. The LTA describes two mounting methods: extended fence posts, usually inset 4.0 m from the back of the court on the side elevations, or stand-alone columns outside the enclosure. SAPCA adds a third method for covered courts, with fittings on the roof structure at 6.0 m eaves height. SAPCA calls the extended posts the preferred option. Stand-alone columns may suit a site with homes close by, where spill and glare need tighter control.

Building a padel court, including 3 m and 4 m fencing and lighting posts, needs formal planning consent from the local authority. SAPCA says a lighting design pack is part of that application, and that a noise assessment is often required if homes stand 30 m to 50 m away. Designs next to homes should also be checked against the ILP Guidance Notes for the Reduction of Obtrusive Light 2021. Polaris can survey the court, produce a lighting design pack for planning, and supply and install the fittings.

If you are converting existing lights to LED, the scheme still needs to meet 300 lux or 500 lux with a 0.9 maintenance factor. Check that any current consent was discharged, and check the posts or columns. If an outdoor court may later be covered, the LTA says the indoor standard should be adopted from the start, or provision made in the switchgear and cabling.

This guide and our padel court lighting page

This page is the guide: how to light a padel court, LTA and SAPCA lux levels, glass-court layouts, planning permission and a downloadable PDF. Our padel court lighting page is the service page, with product options and a request for a survey. You may also want our tennis court floodlighting guide, or the sports lighting overview.

Frequently asked questions

How many lux does a padel court need?

The LTA Padel Court Data Sheet and the SAPCA Code of Practice (September 2025) both set 500 lux average illuminance with 0.7 uniformity for national and international competition, and 300 lux with 0.5 uniformity for regional competition, school and recreational use. The figures are at ground level (Z=0), and they apply to outdoor and indoor courts. A 0.9 maintenance factor should be built into the design.

Do indoor and outdoor padel courts use the same lux levels?

Yes. In the LTA and SAPCA tables, the 300 lux and 500 lux figures are the same for outdoor and indoor courts. If an outdoor court may later be covered, the LTA says the indoor standard should be adopted from the start, or provision made for a later upgrade.

Do padel court lights need planning permission in the UK?

Yes. The LTA says building a padel court is development and needs formal planning consent, including for 3 m and 4 m fencing and for floodlighting posts and fittings. SAPCA says a lighting design pack is part of the application, and a noise assessment is often required if homes are 30 m to 50 m away.

How high should padel lights be mounted?

The LTA, SAPCA and the FIP Rules of Padel all require at least 6 m of clear height above the playing area, measured to the underside of the fittings. For new facilities, 8 m is recommended where it is feasible. Extended fence posts and stand-alone columns are usually inset 4.0 m from the back of the court, on the side elevations.

Why does a glass padel court need a different lighting approach?

Play uses the glass and mesh walls, so players watch a ball come off the surface and often look up into the lights. A design that only reports horizontal lux on the floor can miss glare and uneven light on the walls. SAPCA says planning authorities may ask for vertical lighting calculations. A sport-specific, cut-off optic matters more here than a general amenity floodlight.

Can we convert existing padel floodlights to LED?

Often yes, but the new scheme still needs to be designed to the current 300 lux or 500 lux standard, with a 0.9 maintenance factor. Check that any existing planning consent was discharged, and check the posts or columns. On a glass court, a cut-off LED optic helps control glare on the walls.

What fittings does Polaris use for padel?

PS-PADEL-LINEAR is a slim linear LED for indoor and covered courts, with a P30 cut-off optic, an Inventronic remote driver and a 5-year warranty. PS-POWER is the outdoor floodlight, with a 100 x 60 degree padel optic at 5000K, an optional visor, and a 5-year warranty.

How do I get the padel court lighting guide?

Enter your name, organisation and email in the form on this page. You can download the free 8 page PDF straight away. You can also ask for a free survey if you are planning a project.

Free floodlighting survey

Every Polaris product carries a 5-year warranty. Tell us about your courts and we will send you a lux plot and proposal with no obligation.

Request my free survey